Rajal Industries

Anchor bolts (M24–M36) wrong projection length: base plate won’t sit, crew loses 1 day

Anchor bolts

Anchor bolts with wrong projection length are a site failure nobody plans for

The column arrives.
The base plate is lowered.
The holes don’t line up.
Or worse — the bolts are too short.
No thread left above the nut.
No room for washers.
No way to tighten.
This problem — anchor bolts with wrong projection length — regularly causes installation delays, rework, and crew idle time on PEB and industrial building sites.
And it usually costs at least one full day.

Why projection length matters

Projection length is not random.

It must account for:

  • Base plate thickness
  • Grout thickness
  • Leveling plate thickness (if any)
  • Washer thickness
  • Nut height
  • Tolerance and adjustment

If any of these is underestimated, the bolt becomes unusable.

How wrong projection length happens

1. Design vs site mismatch

Drawings assume theoretical grout thickness.

On site:

  • Grout is thicker
  • Leveling shims are added
  • Tolerances accumulate
    Suddenly the bolt is too short.
  •  
  • 2. Template errors
    Anchor bolt templates:
    • Shift during concreting
    • Bend under load
    • Are not fixed rigidly
      When templates move, bolt position and projection change.
    •  
    • 3. Incorrect cutting or fabrication
      For straight anchor rods:
      • Rods cut too short
      • Threads not extended enough
        For J/L bolts:
      • Bend radius changes effective length
      •  
      • 4. Misinterpretation of drawings
        Some drawings show:
        • Embedment length
        • Some show total length
        • Some show projection only
          Misreading leads to wrong fabrication.
        •  

        Typical anchor bolt specs in PEB

        Common anchor bolt sizes:

        • M24 × 750–900 mm
        • M30 × 900–1100 mm
        • M36 × 1100–1300 mm
        •  

        Common types:

        • J bolts
        • L bolts
        • Straight rods with anchor plate
        •  

        Finish:

        • Black for embedment
        • HDG for exposed portion
        •  

        What wrong projection length causes

        • Base plate won’t sit
        • Nuts won’t engage fully
        • Washers can’t be installed
        • Emergency cutting or welding
        • Structural compromise
        • Crew idle time
        • Audit remarks
        •  

        How to prevent anchor bolt projection failures

        Always calculate projection from full stack-up
        Include grout and shim allowance
        Fix templates rigidly before concreting
        Mark projection on rods before pour
        Inspect after concrete but before erection
        Keep contingency washers and extra nuts

        Final thought

        Anchor bolts are installed first — but tested last.
        When they’re wrong, everything above them suffers.
        That’s why getting anchor bolt projection length right is not just a detail.
        It’s the foundation of the whole structure.